Size : 50mm/2'' or 80mm/3''
Accuracy: ±0.2%
Repeatability: ≤0.05%
Working temperature:-40°C~60°C

The SM Series Positive Displacement Flow Meter is designed for accurate liquid measurement using a mechanical measuring mechanism. Its main components include a mechanical counter, gear assembly, regulator, drive gear, connector, cylinder block, rotor assembly, and blades.
Under system pressure, the rotor and blades rotate, allowing the blades to reciprocate along the cylinder curve and discharge liquid quantitatively. The mechanism transmits movement to the mechanical counter for flow measurement.
Key components are made of alloy materials and engineering plastics, providing corrosion resistance, wear resistance, and sealing performance for demanding liquid metering applications.
FLUID: Biodiesel | Diesel | HVO | XTL | Gasoline | Kerosene
| Parameter | SM-50 | SM-80 |
|---|---|---|
| Size | 50 mm / 2″ | 80 mm / 3″ |
| Volume per Revolution | 0.4 L / 0.1 US gal | 2.27 L / 0.6 US gal |
| Minimum Flow Rate | 40 L/min | 133.3 L/min |
| Maximum Flow Rate | 400 L/min | 1,333 L/min |
| Accuracy | ±0.2% | ±0.2% |
| Repeatability | ≤0.05% | ≤0.05% |
| Working Temperature | -40°C to +60°C | -40°C to +60°C |
| Maximum Viscosity | 800 cP / 3,850 SSU | 800 cP / 3,850 SSU |


The selection should be based on the required flow range, pipeline size, liquid properties, and operating conditions. The SM-50 covers 40–400 L/min, while the SM-80 covers 133.3–1,333 L/min. The actual operating flow should fall within the selected model’s specified range.
Under system pressure, the rotor and blades move within the measuring chamber to create repeated displacement cycles. The resulting mechanical movement is transmitted to the register, which records the measured liquid volume.
Liquid viscosity affects the resistance to flow and the operating behavior of a meter. Checking the specified viscosity limit alongside the flow range and pressure conditions helps ensure the selected model suits the liquid and intended application.
The specified ±0.2% accuracy describes measurement performance relative to a reference, while repeatability of ≤0.05% indicates the consistency of repeated measurements under comparable conditions. Both values matter when evaluating industrial measurement and inventory control requirements.
The system designer should review the actual flow rate, pipeline size, liquid viscosity, operating temperature, pressure conditions, and required measurement performance. The meter’s installation orientation and connection arrangement should also be checked against the manufacturer’s installation instructions.
Positive Displacement Flow Meter with Robust positive displacement mechanical design and Low pressure loss, long service life,another features is Calibrator adjustable to 0.2% custody accuracy.
|
Model
|
SM-50
|
SM-80
|
|
Size
|
50mm/2''
|
80mm/3''
|
|
Volume per Revolution
|
0.4L/0.1US Gallons
|
2.27L/0.6US Gallons
|
|
Min Flow Rate
|
40L/Min
|
133.3L/Min
|
|
Max Flow Rate
|
400L/Min
|
1333L/Min
|
|
Accuracy
|
±0.2%
|
±0.2%
|
|
Repeatability
|
≤0.05%
|
≤0.05%
|
|
Working Temperature
|
-40°C~60°C
|
-40°C~60°C
|
|
Max Viscosity
|
800cps/3850 SSU
|
800cps/3850 SSU
|