Voltage :110v/ 220V
Flow rate : 80L/Min
Power:550W
Max Pressure: 3Bar

The ACTP80 Diesel Fuel Transfer Pump is designed for transferring diesel and other compatible fuels in workshops, fleet fueling operations, and industrial applications. Equipped with a 550W electric motor, an internal bypass valve, and a vane pump mechanism, it delivers a maximum rated flow of 80 L/min. The pump supports 110V or 220V power configurations and features an IP55-rated enclosure, a 1-inch connection size, and a specified single-use operating time of 30 minutes, making it suitable for compatible fuel transfer tasks within its operating limits.
| Parameter | Specification |
|---|---|
| Model | ACTP80 |
| Product Type | Electric Diesel Fuel Transfer Pump |
| Power Supply | 110V / 220V |
| Rated Power | 550W |
| Maximum Flow Rate | 80 L/min |
| Maximum Working Pressure | 3 bar |
| Inlet / Outlet Size | 1 inch |
| Pump Mechanism | Vane Pump |
| Bypass Valve | Integrated |
| Enclosure Protection | IP55 |
| Single-Use Operating Time | 30 minutes |
| Compatible Fluids | Diesel, HVO, XTL, Kerosene |
| Package Quantity | 2 pcs/carton |
| Carton Dimensions | 38 × 19 × 19 cm |
| Carton Weight | 27.5 kg/carton |

Higher Rated Flow Capacity
The ACTP80 has a maximum rated flow of 80 L/min, making it suitable for applications requiring a higher transfer rate. Actual performance depends on the fuel properties, suction conditions, pipework, and discharge resistance.
Flexible Power Supply Options
The 110V and 220V configurations support different installation requirements. Select the correct model according to the local power supply and verify the rated frequency before operation.
Integrated Bypass and Thermal Protection
The bypass valve supports internal fuel circulation under suitable conditions, while thermal protection helps protect the motor from overheating. Both functions should be used according to the manufacturer’s instructions.
IP55 Enclosure Protection
The IP55 rating indicates protection against harmful dust ingress and water jets under specified test conditions. It does not mean the pump is waterproof or suitable for immersion. Installation conditions must remain within the manufacturer’s environmental limits.
Defined Operating Duration
The catalog specifies a 30-minute single-use operating time. Follow the manufacturer’s instructions regarding operating duration, rest periods, and cooling before restarting the pump.
The ACTP80 has a maximum catalog-rated flow of 80 L/min. This rating indicates its specified maximum transfer capacity under suitable conditions, not a guaranteed flow rate in every installation. Actual output depends on suction lift, fuel viscosity, hose diameter and length, filters, fittings, and discharge pressure.
The principal difference shown in the catalog is the maximum rated flow: 65 L/min for the ACTP65 and 80 L/min for the ACTP80. Both are listed with a 550W motor, 110V/220V power options, and a maximum working pressure of 3 bar. Select the model according to the required operating flow and verify the intended duty cycle and installation conditions.
IP55 indicates that the enclosure provides protection against harmful dust ingress and water jets under defined test conditions. It does not indicate that the pump can be submerged in water or exposed to every outdoor condition. Protect the pump from unsuitable weather, standing water, and environmental conditions outside the manufacturer’s specified limits.
The supplied catalog specifies a single-use operating time of 30 minutes. This should be treated as an operating limit unless the manufacturer provides different instructions for the specific configuration. Confirm the required rest or cooling period before restarting the pump, particularly in installations involving frequent or repeated fuel transfers.
The catalog lists diesel, HVO, XTL, and kerosene. Before operation, confirm compatibility between the selected fuel and all pump components, hoses, and seals. Also check the electrical supply, 1-inch connections, maximum working pressure of 3 bar, suction conditions, and the specified 30-minute operating duration. Use appropriate fuel-handling and electrical safety measures for the installation environment.
Features:
In the range of diesel transfer pumps, this electric pump consists of a by-pass valve for precise adjustment of the quantity of flow transferred, while dispensing, with a flow rate of up to 80 l/min. The vane pump with sintered steel rotor and acetal resin vanes, and the induction motor with aluminum casing make this diesel electric pump suitable for continuous cycle applications, requiring a reliable and quality product. The thermal protection protects it in case of motor overloads.
· Self-priming diesel fuel transfer pump
· Only suitable with diesel or biodiesel, kerosene
· Pumping speed 80ltr per min. 220v
· Direct drive, self-priming, vane pumping units, 1" BSP ports
· Switch & 2m long mains cable. Internal bypass
· Weatherproof to IP55 for outdoor use
· Continuously rated motor
Specification
| Product | electric fuel dispenser pump |
| Model number | ACTP80 |
| Flow(LPM) | 80 |
| Speed(RPM) | 1400 |
| HP | 1 |
| Watts | 550w |
| Diameter | 1" BSP |
| Material | cast iron |
| Volt | 220V |
| Bypass valve | yes |
| Self priming | yes |
| Seal type | lip |