ACTP100 Diesel Fuel Transfer Pump

FLUID: Biodiesel | Diesel/HVO/XTL | Kerosene

MODEL NUMBER: ACTP100

APPLICATION:

FEATURES

Voltage : 220V

Flow rate : 100L/Min

Power:1000W

Max Pressure: 3Bar

REQUEST
INFORMATION
DESCRIPTION TECHNICAL DETAILS VIDEO MANUAL

Description

The ACTP100 Diesel Fuel Transfer Pump is designed for transferring diesel and compatible alternative fuels in industrial, agricultural, and equipment refueling applications. Available in 110V and 220V configurations, it provides a flexible power option for different installation requirements.

With a specified flow rate of 100 L/min, a maximum working pressure of 3 bar, and a 1¼-inch inlet/outlet, the ACTP100 is designed for fuel transfer systems that require a larger nominal connection size and high transfer capacity. Its motor housing and mounting base support installation in compatible fuel handling equipment.

Key Features

  • 100 L/min Flow Rate: Designed for fuel transfer applications requiring a high nominal flow rate.
  • 110V/220V Options: Supports selection according to the available electrical supply.
  • 3 Bar Maximum Working Pressure: Provides a defined pressure limit for system planning.
  • 1¼-Inch Inlet/Outlet: Supports connection to compatible piping and transfer equipment.
  • Multiple Fuel Compatibility: Specified for diesel, HVO, XTL, and kerosene.
  • 30-Minute Operating Limit: The specified maximum single operating time is 30 minutes.

Applications

  • Diesel transfer for agricultural and construction machinery
  • Industrial fuel storage and distribution
  • Equipment refueling systems
  • Fuel transfer between tanks and containers
  • Suitable fixed fuel transfer installations

Technical Specifications

ParameterSpecification
ModelACTP100
Product TypeDiesel Fuel Transfer Pump
Voltage110V/220V
Power750W (model heading)
Flow Rate100 L/min (model heading)
Maximum Working Pressure3 bar
Inlet/Outlet1¼ inch
Maximum Single Operating Time30 minutes
Compatible FluidsDiesel, HVO, XTL, kerosene
Quantity per Carton1 pc
Carton Size40 × 19 × 26 cm
Weight per Carton16.8 kg

Why Choose the ACTP100?

The ACTP100 is intended for fuel transfer systems requiring a high nominal flow rate and a larger inlet/outlet connection. Its 110V/220V power options provide flexibility when specifying equipment for different markets and installations.

For distributors, equipment manufacturers, and industrial users, the ACTP100 can be considered for compatible diesel transfer and refueling systems. Correct selection requires checking the actual motor rating for the chosen voltage version, connection compatibility, system resistance, fuel requirements, and operating duration.

Frequently Asked Questions

1. What is the ACTP100 Diesel Fuel Transfer Pump used for?

The ACTP100 is designed to transfer compatible fuels between tanks, containers, and equipment. It can be considered for agricultural machinery, construction equipment, industrial fuel handling, and fuel distribution installations where its electrical configuration, connection size, and operating limits match the application.

2. Which fuels are compatible with the ACTP100?

The product information lists diesel, HVO, XTL, and kerosene. Before transferring a particular fuel, verify compatibility with the pump’s internal components, seals, hoses, and fittings. Compatibility with gasoline or other solvents should not be assumed unless explicitly confirmed by the manufacturer.

3. How should buyers choose between the ACTP90 and ACTP100?

The ACTP90 is specified at 90 L/min with a 600W motor and 1-inch inlet/outlet, while the ACTP100 is presented with a 100 L/min flow rate and a 1¼-inch inlet/outlet. The ACTP100 may be more appropriate when the system requires the larger connection size and higher nominal flow. Actual performance depends on the complete installation, and the specifications for the selected voltage version should be confirmed before ordering.

4. What should be considered when installing the ACTP100 in a fuel transfer system?

Check the electrical supply, pump connection size, pipework, hose compatibility, required flow rate, and maximum working pressure. The entire system must be suitable for the intended fluid and installation environment. Proper electrical protection and compliance with applicable fuel-handling regulations are also important.

5. Is the ACTP100 suitable for continuous fuel transfer?

The supplied product information specifies a maximum single operating time of 30 minutes. This does not establish continuous-duty capability. If the application requires longer or repeated operation, obtain the manufacturer’s permitted duty cycle and rest interval before selecting the pump for that task.

Features:

In the range of diesel transfer pumps, this electric pump consists of a by-pass valve for precise adjustment of the quantity of flow transferred, while dispensing, with a flow rate of up to 100 l/min. The vane pump with sintered steel rotor and acetal resin vanes, and the induction motor with aluminum casing make this diesel electric pump suitable for continuous cycle applications, requiring a reliable and quality product. The thermal protection protects it in case of motor overloads.

·  Self-priming diesel fuel transfer pump

·  Only suitable with diesel or biodiesel, kerosene

·  Pumping speed 100ltr per min. 220v

·  Direct drive, self-priming, vane pumping units, 1″ BSP ports

·  Switch & 2m long mains cable. Internal bypass

·  Weatherproof to IP55 for outdoor use

·  Continuously rated motor

Specification

Product electric fuel dispenser pump
Model number ACTP100
Flow(LPM) 100
Speed(RPM) 1400
HP 1
Watts 1000w
Diameter 1″ BSP
Material cast iron
Volt 220V
Bypass valve yes
Self priming yes
Seal type lip

ACTP100 VIDEO
No data
LEAVE YOUR MESSAGE SOON
                 