AC-TM Series Electric Measuring Turbine Flow Meter

FLUID: Diesel/HVO/XTL | Kerosene

MODEL NUMBER: AC-TM Series

APPLICATION:

FEATURES

Size : NPT 1'' or 1.5'' or 2''

Accuracy: ±1%

Max Working Pressure: 0.7mpa

Materials : Alu or Stainless steel

REQUEST
INFORMATION
DESCRIPTION TECHNICAL DETAILS VIDEO MANUAL

Product Description

The AC-TM Series Electric Measuring Turbine Flow Meter features high accuracy, durable performance, and a compact design. It is mainly used to transfer and measure light oils such as diesel and gasoline. Its module design can be used with an output module, sensor, and long-distance transfer systems. The meter is available with aluminum or stainless steel construction and supports a range of pipe connection sizes and flow rates.

Key Features

  • High-Precision Measurement: Measurement accuracy up to ±1%, suitable for industrial liquid measurement requirements.
  • Repeatable Measurement: Repeatability of ±0.3% for consistent readings during repeated filling operations.
  • Turbine Measuring Mechanism: Designed for light-oil flow measurement with durable internal components.
  • Multiple Flow Rate Options: Available in different connection sizes, with flow rates from 5–75 L/min to 40–400 L/min, depending on the model.
  • Multiple Display Units: Four measurement units are available for selection.
  • Clear Digital Display: The large LCD screen simultaneously shows single-fill volume and total cumulative volume.
  • Simple Operation: The panel features clearly marked buttons for calibration, display switching, and resetting the subtotal.
  • Long-Lasting Power Supply: Powered by standard AA batteries for convenient replacement.
  • Multiple Material Options: Aluminum or stainless steel construction is available; the catalog also lists Teflon.
  • Module Compatibility: The module design supports use with an output module, sensor, and long-distance transfer systems.

Applications

  • Diesel and gasoline transfer
  • HVO and XTL fuel measurement
  • Kerosene transfer
  • Industrial liquid dispensing
  • Fuel transfer systems with compatible hoses and threaded connections
  • Applications requiring flow monitoring and cumulative volume recording

Technical Specifications

ParameterSpecification
SeriesAC-TM
Meter TypeElectric Measuring Turbine Flow Meter
Accuracy±1%
Repeatability±0.3%
MaterialsAluminum, stainless steel, Teflon
Maximum Pressure0.7 MPa
Battery Power2 × 1.5V
Measurement Units4 selectable units
Subtotal DisplayUp to 9999.9
Total DisplayUp to 999999
Compatible FluidsDiesel / HVO / XTL / Kerosene

Model and Flow Rate Options

ModelInlet / OutletFlow Rate
AC-TM0.75BSP/NPT 3/4″5–75 L/min
AC-TM1BSP/NPT 1″10–100 L/min
AC-TM1.5BSP/NPT 1.5″20–200 L/min
AC-TM2BSP/NPT 2″30–300 L/min
AC-TM3BSP/NPT 3″40–400 L/min

Product Advantages

High-Precision Measurement

Measurement accuracy up to ±1%, meeting industrial liquid measurement requirements for diesel, gasoline, kerosene, and compatible chemicals. Repeatability of ±0.3% supports consistent results across repeated measurements.

User-Friendly Design

The large LCD screen simultaneously shows single-fill volume and total cumulative volume for intuitive reading. The panel features clearly marked buttons:

  • CALIBRATE: Used for device calibration.
  • DISPLAY: Used to switch the displayed content and query data.
  • One-Touch Zero Reset: Conveniently initiates new metering tasks.

Reliable Internal Quality

The internal movement features a high-quality PCB electronic module, compact structure, and stable signal transmission. The standard AA battery power supply offers low power consumption and convenient battery replacement.

Robust Durability and High Performance

The turbine core is designed for extended service life, wear resistance, and corrosion resistance. Multiple connection sizes support different flow requirements, from 5–75 L/min to 40–400 L/min.

FAQ

1. What liquids can the AC-TM Series measure?

The catalog lists diesel, HVO, XTL, and kerosene. The product description also mentions gasoline and compatible chemicals. Actual suitability depends on fluid compatibility with the selected meter materials and operating conditions.

2. How do I choose the correct AC-TM model?

Choose according to the required flow rate and pipe connection size. The series offers 3/4″, 1″, 1.5″, 2″, and 3″ connections, with corresponding flow ranges from 5–75 L/min to 40–400 L/min.

3. What information can the LCD display show?

The large LCD screen displays single-fill volume and total cumulative volume. The catalog also describes a DISPLAY button for switching displayed content and querying data.

4. How is the AC-TM flow meter powered?

The catalog specifies a battery power supply of 2 × 1.5V and describes the use of standard AA batteries. Confirm the battery specification and replacement requirements for the selected model before ordering.

5. Can the AC-TM Series be used in a long-distance transfer system?

The catalog states that its module design can be used with an output module, sensor, and long-distance transfer systems. Confirm the required output module and sensor configuration for the intended installation.

Operating Note

Confirm the required connection standard, liquid compatibility, operating pressure, and flow range before ordering. The catalog lists BSP/NPT connection options; specify the required thread standard when selecting a model.

Model AC-TM1AC-TM1.5AC-TM2
Inlet / outletNPT1”NPT1.5”NPT2”
Accuracy±1%±1%±1%
MaterialsAlum 304 /stainless steel Alum 304 /stainless steelAlum 304 /stainless steel
Max pressure0.7mpa0.7mpa0.7mpa
Battery power2 x 1.5v2 x 1.5v2 x 1.5v
Flow rate10-100L/Min20-200L/Min30-300L/Min

Instruction of AC-TM1 Flow Meter

This flow meter has an LCD digital display board that shows instantaneous flow and flow rate.

‍
Press Display Button to return instantaneous flow readings to zero.

‍
Press Calibrate button to show cumulative flow readings on the display,

‍
Press Calibrate button for more than 3 seconds until the unit twinkle to enter the coefficient calibration and unit setting mode. Then press the Display button to choose the number you want to adjust, when the number flashes, press Calibrate button to adjust. When the unit twinkles, press calibrate button to choose the unit between liters, gallons, pints, and quarts. After adjustment, just wait for 5 seconds to exit the adjustment mode.

‍

Specification:

Model AC-TM1 AC-TM1.5 AC-TM2
Inlet / outlet NPT1'' NPT1.5'' NPT2''
Accuracy ±1% ±1% ±1%
Materials Alum 304 /stainless steel Alum 304 /stainless steel Alum 304 /stainless steel
Max pressure 0.7mpa 0.7mpa 0.7mpa
Battery power 2 x 1.5v 2 x 1.5v 2 x 1.5v
Flow rate 10-100L/Min 20-200L/Min 30-300L/Min