Match the pump to your site — not the other way around
Start with the working condition, then match the power source, flow rate, duty cycle and pump type. Mining, construction, agriculture, fleet refuelling, generators, mobile service and fixed tank systems all need different transfer solutions.
Most buyers don't start from a model number — they start from a site. Pick the condition that looks
like yours and you'll get the recommended pump type, the key specifications, and the models we ship
most often to that kind of project.
01
Mining Site
Remote mining and quarry sites need either portable 12V transfer near the equipment or a high-flow fixed system for bulk refuelling. Select by required throughput, available power and the site's hazardous-area requirements.
Recommended
YB-80 · DCEX100 · DCEX200
12V / 380V30–700 L/minGasoline compatibleFixed / mobile options
Excavators, loaders and other heavy equipment are often refuelled directly on site. A portable 12V pump works for service-vehicle refuelling, while YB-80 covers higher-throughput fixed systems.
Recommended
DCEX100 · DCEX200 · YB-80
12V / 380V30–700 L/minGasoline compatiblePortable + high flow
Tractors and agricultural machinery may be refuelled in the field or from a fixed farm tank. The selected range covers compact 12V transfer and higher-flow fixed fuel supply.
Where permanent AC mains are unavailable, the 12V DC models can connect to a vehicle or equipment power source for portable transfer. This makes them better suited to temporary and remote refuelling points.
Recommended
DCEX100B · DCEX100 · DCEX200
12V DCQuick-connect power≈15–30 L/minNo fixed AC mains
Fleet refuelling can range from a portable truck-mounted transfer point to a high-throughput depot. Use 12V DC models for mobile service or YB-80 where fixed bulk transfer capacity is the priority.
Standby generators need compact, controlled fuel transfer and are often serviced where portable DC power is more convenient than a permanent pump installation.
For field-service vehicles and temporary refuelling points, portability and 12V quick-connect power matter more than a permanent installation. These three models are the strongest fit from the selected set.
Fixed tank and depot systems can use YB-80 for high-flow gasoline-compatible transfer. ACTP65QP adds preset dispensing and printed records, but its current product listing is for diesel/HVO/XTL and kerosene rather than gasoline.
These five models replace the previous diesel-focused product set. YB-80, DCEX100B, DCEX100 and DCEX200 are listed by Aocheng as gasoline-compatible. ACTP65QP is included as the requested preset-printer option, but its current product listing specifies diesel/HVO/XTL and kerosene rather than gasoline.
Not sure which condition fits? Send us a photo of the fuel source and the machine you're refuelling. We can use the site condition, target flow, available voltage and hose distance to narrow the pump type and configuration.
Step 2 · Technical Overview
Pump Types at a Glance
Compare the five selected models by power, flow and fuel compatibility. Gasoline compatibility is model-specific: YB-80, DCEX100B, DCEX100 and DCEX200 are listed for gasoline; ACTP65QP is currently listed for diesel/HVO/XTL and kerosene.
Pump type
Representative models
Power
Flow rate
Media
Best suited to
High-flow vortex pump
YB-80
380V
700 L/min
Biodiesel · Diesel/HVO/XTL · Gasoline · Kerosene
Tank & depotConstruction / agricultureHigh throughput
Portable EX-proof pump
DCEX100B
12V
3.7 GPM (~15 L/min)
Biodiesel · Diesel/HVO/XTL · Gasoline · Kerosene
Off-gridGeneratorMobile refuelling
Portable EX-proof pump
DCEX100
12V
30 L/min
Diesel/HVO/XTL · Gasoline · Kerosene
ConstructionFleetGenerator
Preset pump with printer
ACTP65QP
220V
40 L/min
Diesel/HVO/XTL · Kerosene
Preset dispensingPrinted recordsNot listed for gasoline
Portable EX-proof pump
DCEX200
12V
30 L/min
Diesel/HVO/XTL · Gasoline · Kerosene
Mobile tanksGeneratorService work
Fuel compatibility is taken from Aocheng's current product listings. ACTP65QP is retained because it was included in the requested model set, but it is not currently listed as gasoline-compatible.
These are the operating problems buyers face in the field — unstable power, moving refuelling points, fast installation requirements and harsh job-site conditions. Each card shows the practical advantage Aocheng can offer for that condition.
For remote pits, farms and temporary work zones, selected 12V / 24V Aocheng DC pumps can connect to a vehicle or equipment battery. The operator does not need permanent AC mains at the refuelling point.
12V / 24V DCBattery connectionRemote-site ready
02MOBILE REFUELLING
REFUELLING POINT KEEPS MOVING
Take the pump to the machine
When excavators, tractors or service vehicles are spread across a site, a compact transfer pump can move with the job. This reduces unnecessary travel back to a fixed fuel station and makes field refuelling more flexible.
PortableVehicle / trailer useField refuelling
03QUICK-CONNECT KIT
FAST SETUP, FEWER CONNECTIONS
Connect a complete kit and start faster
Aocheng transfer kits can combine the pump, hose, nozzle, filter and optional meter in one matched setup. That makes installation simpler and reduces the time spent sourcing and connecting separate components on site.
Pump + hoseNozzle + filterQuick deployment
04HARSH JOB SITE
DUST, HEAT & REMOTE MAINTENANCE
Choose a model built around the site conditions
Mining and construction sites often combine dust, heat, long working hours and limited maintenance access. Aocheng models can be selected by published duty cycle, temperature range, IP protection and fluid compatibility instead of relying on a one-size-fits-all pump.
Reading a specification sheet only goes so far. These short clips show the pumps running in our
workshop and in the field — priming, metering and refuelling at real working speed.
Pump kit assembly and priming — what you receive in the box
Flow rate demonstration with the digital meter counting litres
Battery-clamp connection shown end to end, off-grid
Aocheng's company history traces its fuel-handling roots to a refuelling-nozzle business in 1983. Current company data lists 4 manufacturing bases, 10 production lines, 48 products and 168 patents. For this category, buyers can source pumps together with related hose, nozzle, meter and filtration components.
Below are the lines we hear most often from buyers in Africa, the Middle East and South-East Asia,
and what we can actually commit to on each one.
Aocheng's published company history traces its fuel-handling roots to a refuelling-nozzle workshop in 1983. We describe this as industry history rather than using it as a disputed incorporation date.
48 Products · 168 Patents
Company overview data in the supplied crawl lists 48 products and 168 patents, alongside 10 production lines and 4 manufacturing bases.
Flexible OEM / ODM
Configuration options can include branding, colour, voltage, flow rate, hose length, nozzle type, meter, filtration, packing and documentation, depending on the product.
Trial Orders from 1 Unit
Commercial terms provided for this project allow selected standard products to start from one unit, helping buyers test a configuration before larger-volume orders.
Company-Level Certification Matrix
Aocheng lists ISO 9001 plus fuel-transfer and explosion-proof certification resources at company level. Certification must still be confirmed against the exact model and destination-market requirement.
Standard & Custom Lead Times
Commercial guidance provided for this project is about 15 working days for standard products and 25–30 working days for customised OEM configurations.
Customisable
Everything on this list can be specified to match your market and your brand.
A straightforward process designed for first-time importers as much as for experienced distributors —
you'll know the model, the price and the delivery date before you commit to anything.
01
Tell Us the ConditionSITE & DUTY
Send photos of the site, the fuel source and what you're refuelling — plus flow target if you have one.
02
Get a Matched ModelRECOMMENDATION
We reply with the recommended pump type, key specifications and an itemised quotation.
03
Confirm the ConfigurationSAMPLE / SPEC
Lock voltage, flow, hose, nozzle, meter and branding. Custom options are confirmed in writing.
04
Production & QC15–30 DAYS
Batch production with inspection before packing. Photos and video of your units before shipment.
05
Ship & SupportFOB / CIF / DDP
Documents prepared for your port. Spare parts and remote support continue after delivery.
What to Include in Your Inquiry
Working conditionMining / construction / farm / fleet / generator / mobile / depot — a photo works best
Power availableMains 220V · truck battery 12V / 24V · nothing at all (manual pump needed)
MediaDiesel, petrol (explosion-proof required), kerosene or other
Target flowL/min you need, or tank size and how fast you want it filled
QuantityTrial quantity and estimated annual volume — both help us quote correctly
DestinationCountry / nearest port, so we quote the right shipping term
Trade Terms
MOQ1 unit for trial ordersVolume pricing from container quantities
Lead time≈15 working days standardCustom configuration: 25–30 working days
Shipping termsFOB · CIF · DDU · DDP
PaymentDiscuss with our sales teamTerms arranged per order size and region
After-salesField-replaceable spare parts + remote video support
Buyer Questions
Frequently Asked Questions
The questions buyers ask most before ordering a fuel transfer pump for a project site.
What size fuel transfer pump do I need for my project?
Start with five inputs: fuel type, available voltage, target flow rate, duty cycle and installation method. The crawled Aocheng range includes small manual and 12V/24V mobile pumps, 220V fixed pumps and higher-flow industrial systems. Use the individual product specification to choose the final model.
Can a fuel transfer pump run without mains electricity?
Yes. DCTP40 Battery is listed as a 12V/24V pump that connects to a vehicle battery, while manual models such as TS-50 and TS-51 require no electrical supply. Choose according to the required transfer volume and site setup.
What is the difference between a diesel and a gasoline transfer pump?
Fluid compatibility and safety design are model-specific. Do not assume a diesel-only pump is suitable for gasoline. For gasoline or other flammable fuels, choose a product page that explicitly lists the fuel and the appropriate explosion-proof motor or certification documentation.
Which pump works in 45–50 °C heat and dusty sites?
Do not apply one temperature rating to the whole range. The supplied crawl shows model-specific values—for example, DCEX100, DCEX100B and DCEX200 list -10 °C to +40 °C. For hotter or dustier sites, confirm the exact temperature, IP rating, duty cycle and protection requirements before ordering.
Which spare parts should I stock for a remote site?
For remote projects, plan service parts around the selected model and system. Common items may include hose, nozzle, filters, seals and other wear parts. The exact spare-parts list should be confirmed against the pump configuration rather than using one fixed quantity for every site.
What is the MOQ and lead time?
Commercial terms provided for this project allow selected standard products to start from 1 unit. Guidance is about 15 working days for standard products and 25–30 working days for customised OEM configurations. Confirm the final schedule with the quotation.
Do you support OEM branding and custom configuration?
Yes. Depending on the product, customisation can include colour, logo, voltage, flow rate, hose length, nozzle, meter, filtration, packing and manuals. The exact options and MOQ should be confirmed for the selected model.
Keep Learning
Related Guides & Products
Deeper reading on selection, maintenance and tank systems — written by the same engineers who build these pumps.
Send us your working condition — even just a photo of the fuel source and the machine. We'll match
the pump, confirm the configuration and quote it in one reply.
Site-based model recommendation, not a catalogue dump
Industry roots since 1983 · manufacturing capability